A development of low-cost devices for monitoring indoor air quality in a large-scale hospital

dc.contributor.authorLasomsri P.
dc.contributor.authorYanbuaban P.
dc.contributor.authorKerdpoca O.
dc.contributor.authorOuypornkochagorn T.
dc.date.accessioned2021-04-05T03:03:54Z
dc.date.available2021-04-05T03:03:54Z
dc.date.issued2019
dc.date.issuedBE2562
dc.description.abstractPoor Indoor Air Quality (IAQ) is an issue of environmental health problems that cause headaches, fatigue, irritation of the eyes and skin. IAQ in hospital areas is a serious concern since there are many occupants i.e. patients, medical practitioners, and staffs. Furthermore, medical material, medicine, medical gases can cause the quality of air deteriorate. IAQ then requires to regularly check the service areas in order to maintain a good level of air quality. The instrument to measure IAQ is usually expensive. In this study, a low-cost device to measure IAQ was developed, it comprises of two main sensors: BME680 and CCS811. The device was capable of measuring and recording continuously which allows it to monitor air quality including Total Volatile Organic Compounds (TVOC), temperature and humidity. The device was employed to measure three service areas of a large-scale hospital in Nakhonnayok, Thailand: the waiting area, the emergency room, and the outpatient pharmacy. IAQs of these areas obtained from the developed device were all in the very bad level. It is possibly due to the influence of structural renovation, medical material, air conditioning, air ventilation, and the people occupied in the areas. © 2018 IEEE
dc.format.mimetypeapplication/pdf
dc.identifier.citationECTI-CON 2018 - 15th International Conference on Electrical Engineering/Electronics, Computer, Telecommunications and Information Technology. (2019), p.282-285
dc.identifier.doi10.1109/ECTICon.2018.8619934
dc.identifier.other2-s2.0-85062214639
dc.identifier.urihttps://swu-dspace2.eval.plus/handle/123456789/5493
dc.rights.holderScopus
dc.subject.otherAir conditioning
dc.subject.otherAir quality
dc.subject.otherCosts
dc.subject.otherHospitals
dc.subject.otherMedicine
dc.subject.otherVolatile organic compounds
dc.subject.otherAir ventilation
dc.subject.otherEnvironmental health
dc.subject.otherIndoor air quality
dc.subject.otherLow-cost devices
dc.subject.otherMedical materials
dc.subject.otherMedical practitioner
dc.subject.otherTemperature and humidities
dc.subject.otherTotal volatile organic compounds
dc.subject.otherIndoor air pollution
dc.titleA development of low-cost devices for monitoring indoor air quality in a large-scale hospital