Publication:
Optimization of As(V) adsorption on Fe-RH-MCM-41-immobilized GAC using Box-Behnken Design: Effects of pH, loadings, and initial concentrations

Loading...
Thumbnail Image

Date

Journal Title

Journal ISSN

Volume Title

Publisher

Research Projects

Organizational Units

Journal Issue

Abstract

This work focused on the removal from water of arsenate in the 100 to 500. μg/L range using Fe-RH-MCM-41 immobilized on GAC by a colloidal impregnation method. A Response Surface Method (RSM) based on the Box-Behnken Design (BBD) was used to evaluate the effects of pH, adsorbent loading, and initial arsenate concentrations. The thermal stability of Fe-RH-MCM-41/GAC was greater than 460. °C because Fe-RH-MCM-41 and epoxy resin covered the GAC, preventing GAC weight loss. The rate and capacity for arsenate adsorption on Fe-RH-MCM-41/GAC were higher than for GAC. The effects of pH, adsorbent loading, and initial arsenate concentration showed significant effects on efficiency, in terms of percent arsenate removal. Significant interaction occurred as positive effects between arsenate and arsenate concentrations, and pH and arsenate concentrations, and as negative effects between pH and pH, adsorbent loading and adsorbent loading, and adsorbent loading and arsenate concentrations. © 2011 Elsevier Ltd.

Description

Keywords

Citation

Applied Geochemistry. Vol 27, No.5 (2012), p.1027-1034

Endorsement

Review

Supplemented By

Referenced By