Publication:
On the thermal cooling of central processing unit of the PCs with vapor chamber

dc.contributor.authorNaphon P.
dc.contributor.authorWongwises S.
dc.contributor.authorWiriyasart S.
dc.date.accessioned2021-04-05T03:33:56Z
dc.date.available2021-04-05T03:33:56Z
dc.date.issued2012
dc.date.issuedBE2555
dc.description.abstractAn experimental investigation on the thermal cooling of vapor chamber for cooling computer processing unit of the personal computer is performed. Two different configurations of the vapor chambers with de-ionized water as working fluid are tested under the real operating conditions of PCs. Parametric studies including different aspect ratios, fill ratios, and operating conditions of PC on the CPU temperature are considered. It was found that the vapor chamber cooling technique has significant effect on the thermal cooling of CPU. Average CPU temperatures obtained from the vapor chamber cooling system are 4.1%, 6.89% lower than those from the conventional cooling system for no load and 90% operating loads, respectively. In additional, this cooling system requires 6.89%, 10.53% lower energy consumption for no load and 90% operating loads, respectively. The results of this study are of technological importance for the efficient design of cooling systems of the personal computers or electronic devices to enhance cooling performance. © 2012 Elsevier Ltd.
dc.format.mimetypeapplication/pdf
dc.identifier.citationInternational Communications in Heat and Mass Transfer. Vol 39, No.8 (2012), p.1165-1168
dc.identifier.doi10.1016/j.icheatmasstransfer.2012.07.013
dc.identifier.issn7351933
dc.identifier.other2-s2.0-84865378795
dc.identifier.urihttps://swu-dspace2.eval.plus/handle/123456789/6959
dc.rights.holderมหาวิทยาลัยศรีนครินทรวิโรฒ
dc.subject.otherComputer processing
dc.subject.otherCooling performance
dc.subject.otherCooling technique
dc.subject.otherEfficient designs
dc.subject.otherElectronic device
dc.subject.otherElectronics cooling
dc.subject.otherExperimental investigations
dc.subject.otherNo load
dc.subject.otherOperating condition
dc.subject.otherOperating loads
dc.subject.otherParametric study
dc.subject.otherReal operating conditions
dc.subject.otherThermal cooling
dc.subject.otherVapor chamber
dc.subject.otherWorking fluid
dc.subject.otherAspect ratio
dc.subject.otherCooling systems
dc.subject.otherEnergy utilization
dc.subject.otherPersonal computers
dc.subject.otherProgram processors
dc.subject.otherThermoelectric equipment
dc.subject.otherWater vapor
dc.subject.otherElectronic cooling
dc.titleOn the thermal cooling of central processing unit of the PCs with vapor chamber
dc.typeArticle
dspace.entity.typePublication
swu.datasource.scopushttps://www.scopus.com/inward/record.uri?eid=2-s2.0-84865378795&doi=10.1016%2fj.icheatmasstransfer.2012.07.013&partnerID=40&md5=1b01514a103da5b0b4d6fa2bf37ad97e

Files